2013 TPI Corporation Electrical Heat Products Catalog - page 36

36
Contractor shall supply and install heavy duty ceiling mounted forced air
electric heater(s) of the wattage, voltage and phase as indicated on the plans. The
heater shall so be designed to provide an even distribution of heated air to the space to
be heated by drawing return air in the periphery of the heater, across and through the
element and be discharged from the center section of the heater by mean of an electric
motor and axial flow fan blade.
Motor: Motor shall be permanent lubricated, unit bearing, totally enclosed
shaded pole type with impedance protection. Motors shall operate at no more than
1300 RPM and shall be same voltage as the heater.
Performance: Heaters shall have a rating of 425 CFM at 710 F.P.M. with a
maximum temperature rise of 44°F and 63.9 DB RE 10 12 Watt.
Element: Element assemblies shall consist of two or three corrosion resistant
steel sheathed type elements mechanically bonded to common corrosion resistant
steel fins. Each sheathed element shall consist of helically coiled Nickel Chromium
alloy resistant wire completely embedded in and surrounded by Magnesium Oxide,
enclosed and wedged into corrosion resistant steel sheaths. Elements shall have 2”
cold conductor pins extending into sheath and shall have a density of no more than 60
watts per inch.
Thermal Overload: Heaters shall be equipped with a “manual reset” thermal
overload which disconnects elements and motor in the event normal operating
temperatures are exceeded. For safety, if opened due to abnormal temperature,
thermal overload shall remain open until manually reset. Automatic reset thermal
overloads which allow the element to continue to cycle under abnormal conditions
will not be accepted.
Approval: Heaters shall be ETL listed.
Commercial and Institutional Applications: Use in - vestibules, entrance
ways, lobbies, rest rooms and small office and guard building applications.
Product Dimensions
Product Specifications
Wall Mounted Control Panels
Standard Models
Factory Installed Control Sections
Notes
Optional controls must be factory installed. Field installation is
not acceptable and violates Listing and factory warranty.
Factory installed control sections add 2-5/16” to the height of
the unit.
Wall mounted control panels may control multiple units but
cannot be used if In-Built controls are selected.
480V units include 24V transformer and relay as standard (A1)
- only TS option control section can be added. Depth dimension
of all 480V models is 10-7/8”
Degree F air rise is measured at 710 F.P.M. and 425 CFM. Throw
designed for 8 to 12 foot ceilings. db RE 10
-12
Watt=63.9
Unit weight:
32 lbs.
Recommended Remote Thermostats:
Line Voltage:
Single Phase 208-240V
ET5DS
Single Phase 277V
ET5SS
Three Phase
TW1512
Low Voltage:
UT1001
Manufactured in U.S.A.
*
SUFFIX UNITS
DESCRIPTION
LIST
TS 1-Phase
Single Pole Thermostat - range 40°-110°F and
Disconnect Switch
265
TA1S 3-Phase Single Pole Thermostat - range 40°-110°F & Transformer
with 24V Secondary and 24V Relay & Disconnect Switch 277
A1S 1 or 3
Phase
Transformer with 24V Secondary and 24V Relay and
Disconnect Switch
283
T
Single Pole (480V only)
95
UPC#
686334 MODEL VOLTS CONTACTORS
BOX
LIST
SIZE
605700 AF3401-24 208
1 @ 35 AMPS 12" x 12"
x 4 1/2" 360
605793 AH3401-24 240
605854 AG3401-24 277
605748 AF3402-24 208
2 @ 35 AMPS 15" x 15"
x 4 1/2" 450
605786 AH3402-24 240
605847 AG3402-24 277
605731 AF3403-24 208
3 @ 35 AMPS 18" x 18"
x 4 1/2" 600
605779 AH3403-24 240
605830 AG3403-24 277
UPC#
686334
MODEL KW BTU’S VOLTS PH AMPS TEMP
RISE LIST
367516
F3472
2
6826
208
1
9.6
15 °F
1334
367530
H3472
240
8.3
367523
G3472
277
7.2
324335 P3472A1
480
4.2
1460
470155
J3472
2
6826
208
3
5.6
1431
470162
K3472
240
4.8
470223 Y3472A1
480
2.4
1557
367547
F3473
3 10200
208
1
14.4
22 °F
1366
367561
H3473
240
12.5
367554
G3473
277
10.8
324342 P3473A1
480
6.3
1490
323864
J3473
3 10200
208
3
8.3
1463
470179
K3473
240
7.2
470230 Y3473A1
480
3.6
1587
367578
F3474
4 13600
208
1
19.2
30 °F
1366
367592
H3474
240
16.8
367585
G3474
277
14.4
324359 P3474A1
480
8.3
1490
367608
J3474
208
3
11.1
1475
367837
K3474
240
9.7
324366 Y3474A1
480
4.8
1601
367615
F3475
5 17000
208
1
24.1
37 °F
1532
367639
H3475
240
20.8
367622
G3475
277
18.1
324373 P3475A1
480
10.4
1665
367646
J3475
208
3
13.9
1626
367844
K3475
240
12.1
324380 Y3475A1
480
6.1
1755
International Models
470919 M3472T2i
2
6826
220
1
9.1 15 °F 1334
470926 N3472T2i
240
8.3
470933 M3473T2i
3 10200 220
13.6 22 °F 1366
470940 N3473T2i
240
12.5
470957 M3474T2i
4 13600 220
18.2 30 °F 1366
470964 N3474T2i
240
16.7
3470 Series Commercial Fan Forced Surface Mounted Ceiling Heater
*Optional Adjustable Louver Diffuser - $91 Adder
1...,26,27,28,29,30,31,32,33,34,35 37,38,39,40,41,42,43,44,45,46,...111